Location: Fire dampers are installed in or near the wall or floor, at the point of duct penetration, to retain the integrity and fire rating of a wall or floor whether it is a ducted or open-ple- num return application.

What is a fire damper and where it is fitted?

Fire dampers are ducting fittings. They are usually used whenever there is a fire-resistant wall in the property. Because of the ducting vent, there will be a place through which fire and smoke can escape from one room to another. Fire dampers are what stops the flames and smoke from passing through.

Are fire dampers required in exterior walls?

6) Exterior Walls. Ducts and air transfer openings in fire-resistance rated exterior walls required to have protected openings in accordance with Section 704.14 shall be protected with listed fire dampers in accordance with their listing.

Why are the fire dampers placed in specific locations in the ductwork?

These devices need to be installed at specific locations so that the valves are closed at the right moment when a fire breaks out.

Are fire damper connection to fire alarm?

A fire damper is installed in HVAC duct work at the intersection of a rated barrier such as walls or partitions. … The smoke detector can either be a system smoke (tied to a building fire alarm system) or a stand alone smoke solely in place to activate the smoke damper.

Do fire dampers stop smoke?

Whilst fire dampers function to help stop the passage of fire, smoke dampers work in a similar way to preserve the integrity of physical smoke barriers e.g. floors and walls. … They close upon the detection of smoke and prevent the circulation of smoke and air through the duct or ventilation opening.

Are fire dampers required in 30 minute walls?

As an alternative to this, a fire rated ceiling having a minimum fire resistance of 30 minutes (including light fittings) may be used (Figure 15 ii). When ducts serve a hazard room, then fire dampers are required. (Figure 15 iii).

What is a damper in ductwork?

An HVAC damper (also called a duct damper) is a movable plate, located in the ductwork, that regulates airflow and redirects it to specific areas of the home. Dampers are typically used in zoning or “zone control” systems.

Does a 1 hour fire rated wall require a fire damper?

Q: Are fire dampers required in one-hour fire-rated walls if the facility is fully sprinkled? A: According to NFPA 90A (1999 edition), one-hour fire-rated barriers do not require fire dampers in fully ducted HVAC systems, unless the one-hour fire-rated barrier is a vertical shaft.

What is 1 hour fire rated wall?

According to the Engineered Wood Association, a one-hour rating indicates that a wall constructed in a manner similar to the one tested will contain flames and high temperatures, and support its full load, for at least one hour after the fire begins.

Article first time published on

How do you measure the distance between fires?

The “fire separation distance” is defined in Section 202 as the distance measured from the building face to the closest interior lot line, to the centerline of a street, alley or public way, or to an assumed imaginary line between two buildings on the same lot.

Do exhaust fans require fire dampers?

Smoke dampers are required in HVAC systems with a capacity greater than 15,000 cfm in order to isolate the AHU from duct distribution. The smoke damper on the return side of the system should be installed upstream of its fan.

What is the difference between a fire damper and a smoke fire damper?

A fire damper closes once the duct temperature reaches a high enough level to melt a fusible link. A smoke damper closes upon the detection of smoke. … It is UL leakage-rated to stop smoke in its tracks, which is a main difference from fire dampers.

How do you test a fire damper?

To test if a fire damper is working efficiently, one of the team will release the fire damper manually to ensure it closes fully. In cases of fire the high heat should release the fusible link and close the fire damper to prevent the fire spreading.

How much does a fire damper cost?

The average cost of fire damper testing and inspections is between $40-$150 per fire damper.

Are fire dampers motorized?

Motorized Fire Damper prevents the passage of flame from one side of a fire rated separation to the other and will be functioning with the help of actuators with either an electric or pneumatic actuator. They are controlled by heat detector signal, fire alarm or some other building control system.

How often should fire dampers be checked?

It is recommended that each fire damper must be tested and inspected one year after the installation.

Is fire damper testing statutory?

Under the Regulatory Reform (Fire Safety) Order it is a legal requirement to test fire dampers at regular intervals in accordance with fire safety in the design, management and use of buildings code of practice (BS:9999 2017), using a method known as ‘drop testing’.

Are smoke dampers normally open or closed?

During normal operation the pressure under the floor is maintained by modulating the damper mounted in the shaft wall. If a fire occurs and the temperature at the damper reaches 165°F (74°C), then the damper closes. If smoke is present in duct (or space area), then damper closes.

What is fusible link fire damper?

The damper is held open by a replaceable fusible link. rated at 74 C (U.L. stamped). In the event of the increase. in temperature the fusible link shall melt & the damper. shall close shut with spring action.

Where are zone dampers located?

Dampers are almost always within 2-6 feet of the main trunk. You may only have different style handles, the dampers might be located right off the main trunk or a few feet away, or they might even be rectangular, but you should see something like the image above, cobwebs and all.

Is a firewall required between garage and house?

In short, the garage needs to be separated from the house in case of fire, but this isn’t a fire-rated assembly, nor is it a firewall. The best term for this required separation is a fire-separation wall.

What is the fire rating of 5/8 drywall?

The 5/8-inch, “fire-code” drywall (called Type X) increases a wall’s fire rating to a minimum of 1 hour, from the 30-minute rating for standard ½-inch drywall. And it’s not just thickness that makes the difference. Type X has a denser core and contains glass fibers that keep it from crumbling in the heat.

What are the 3 main classifications of fire rated walls?

Type 1: Fire-resistive: High-rise buildings made of concrete and protected steel. Type 2: Non-combustible: Newer buildings with tilt slab or reinforced masonry walls and a metal roof. Type 3: Ordinary: New or old buildings with non-combustible walls but a wood-framed roof.

Why fire damper is required?

A fire damper is designed to, and required to, close automatically upon detection of heat (such as a fusible link or heat detector) and to interrupt airflow and to restrict the passage of flame.

What is a fire damper actuator?

Belimo safety actuators for fire dampers automatically move to their safety position in case of fire and keep dampers closed during the fire. They offer the best protection against the spread of fire and smoke through ducts.

What is the HS Code for fire damper?

Fire damper and Hs Code 84145990 Export Trade Database.

How many types of fire dampers are there?

There are two types of fire damper closing system: those with a fuse mechanism and those with an actuator, which is motorised, and to which you can connect a smoke detection system.

How are fire dampers powered?

Fire Damper (FD) A fire damper is activated by heat from a fire inside the air duct. The heat can be detected by a fusible link, or by a heat detector in the air duct. Fusible Link – low temperature solder is holding two pieces of metal together.

How does a smoke damper operate?

Fire dampers respond to heat, when the temperature reaches a set point the damper slams shut. Smoke dampers respond to the detection of smoke, and close automatically. They can also be activated remotely. They resist the passage of smoke, toxic gases and air through a fire barrier.

How do you reset a fire damper?

To reset a damper, each stainless-steel blade is repositioned by pushing back the latch under spring tension. Once all the blades have been pushed back, the latch springs out to secure them.